Browse all practice questions for the Structure Cabling Volume Two Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Structure Cabling Volume Two Practice Test course image
Bonding conductors should be marked green with vinyl tape for clear grounding pathsWhich color is specified for marking bonding conductors using vinyl tape?Cat6A performance up to 500 MHz: what it means for copper EthernetPerformance requirements for Cat 6A cables, connectors, basic links, and channels are specified at frequencies up to?Cat6E performance up to 250 MHz: what the frequency rating means for structured cablingThe performance requirements for Cat 6E, cable, connectors, basic links, and cables are specified at frequencies up to?Single-mode fibers have smaller cores than multimode fibers: a quick look at core sizes and light propagationWhich fiber type has a smaller core, Single-Mode or Multi-Mode?The NEC’s main aim is safety: protecting people and equipment through clear electrical standardsWhich statement best describes the NEC's primary goal?TIA-569 Guides Telecommunications Pathways and Spaces.Telecommunications Pathways and Spaces is associated with which standard?Understanding return loss in twisted-pair cabling and how impedance matching affects signalsReturn loss is the measurement of the amount of signal that reflects back to the transmitter as it travels along a twisted-pair encountering impedance discontinuities. Which term describes this measurement?What is the purpose of a Telecommunication Service Bulletin and why it matters for standardsWhat is the purpose of the Telecommunication Service Bulletin (TBS)?Why every floor needs its own telecommunication room in a structured cabling systemThere shall be a minimum of 1 telecommunication room per floor.
More practice questions

These questions are part of the practice quiz. Start practicing

  • What's is the maximum elevation for the termination wall field in a Telecom Room?
  • Which of the following are considerations that affect data transmissions over fiber optic cable?
  • Between 66-block and 110-block configurations, which configuration is described as occupying more space?
  • (T/F) Certification of cable performance requires that the test be documented and reported for future evaluation and/or inspection.
  • Which item is used to describe the material that closes openings to prevent fire spread?
  • Which standard for commercial telecom cable, bonding and grounding would apply to a corporate campus?
  • For 4-pair UTP cable, the minimum bend radius under no-load conditions must be at least how many times the diameter?
  • Which item is commonly used to connect a single circuit from the work area to the distribution point?
  • Horizontal pathways are used to route cables between which two locations?
  • What is the standard for building AUTOMATION cabling?
  • When an installer must change from round type cable to a flat-under carpet, cable is called?
  • TIA standard method for terminating twisted pair cables on 8-pin modular outlets include:
  • Which standard governs color-coding scheme for campus cabling?
  • A conductor interconnects the telecommunications bonding backbone within a multi-story commercial building. What is this conductor called?
  • The performance requirements for Cat 6 cables, connectors, basic links, and channels are specified at frequencies up to how many MHz?
  • The minimum bend radius under no-load conditions for 4-pair UTP cable shall be ________ the cable diameter.
  • The administrative color label for horizontal cables system 1 is?
  • In a 4-pair UTP cable, what is the Pair 1 tip and ring color?
  • Total opposition to alternating current flow is called?
  • Outlet cables shall be home run from outlets to the__________?
  • What does MUTOA stand for?
  • What does PBB stand for?
  • In a 200-pair UTP backbone cable, how many binder groups are there?
  • Exceeding bend radius during installation is most likely to affect which field test parameter?
  • _______________ field testing assures that the cabling link meets the basic connection or continuity requirements.
  • Which cable type has a central copper conductor surrounded by an insulator and an outer metallic shield?
  • Which standard governs administration?
  • Within a video distribution system, every time a pass-through device or 'splitter' is added, the video signal _____________?
  • The minimum bend radius for a bonding conductor is how many times the outside diameter of the conductor?
  • Within how many inches must the pair twists be maintained from the termination point for Cat5 and higher cables?
  • Which NEC article contains definitions?
  • Which standard establishes the grounding and bonding infrastructure for small or large commercial buildings?
  • Underfloor duct systems may be one level or two levels.
  • To verify pin to pin termination at each end of a cable you must select a _______ test.
  • Which of the following is an element of the commercial building tech communication cabling system?
  • Which NEC article addresses Fire Alarm Systems?
  • Which category of field testing is used to ensure a cabling system meets industry performance standards and to document results?
  • Facilities that encompass underfloor duct systems, access floors, under floor conduit, and cable tray or runway used for installing telecommunication cables from the telecom room to the work area telecom outlet are called?
  • Which of the following is not listed as a standard or code referenced in the material?
  • What is the minimum size of a bonding conductor?
  • Which standard addresses commercial telecommunication infrastructure administration?
  • In channel terminology, the fixed portion of the channel is also known as the
  • TIA/EIA 570 Standard covers which area?
  • What device acts as the foundational grounding interface in the telecommunications grounding system?
  • What does the 'U' in 1U refer to in rack-mounted equipment?
  • The minimum bend radius under no-load conditions for 4-pair UTP cable shall be how many times the cable diameter?
  • Which of the following best describes the IBM Type-1 cable structure?
  • Which component serves as a dedicated extension of the building grounding electrode system for the telecommunication room?
  • What provides means for a customer to disconnect from an access provider?
  • (T/F) The performance of the original Type 1 cables was specified at frequencies up to 20 megahertz. The performance of the newer 'A' types (Type 1A) is specified at frequencies up to 300 megahertz.
  • Which material is used to close open parts of a building to prevent the spread of fire and to ensure conduit openings are fire rated?
  • Which term is used when cabling is plugged directly into fixed equipment, where installing a traditional outlet is impractical?
  • Which component provides a common grounding reference inside the telecommunications room?
  • Which busbar is specifically designed to be placed in telecom and equipment rooms to bond telecommunications equipment?
  • Which topic is covered by Article 800 of the NEC?
  • The minimum size conductor of a TBB is what, and the maximum size is what?
  • Which standard governs uniform grounding and bonding infrastructure for building telecommunications?
  • Which statement is true regarding fiber bandwidth and insulation procedures?
  • Outlet cables shall be home run from outlets to the DD. Which option correctly represents DD?
  • Allowing each pair in a twisted-pair cable to have different twists per pair primarily reduces
  • What is the maximum size conductor that can be used as a telecommunications bonding conductor?
  • Which device is added to reduce a video signal to acceptable levels?
  • A Permanent Link can include up to how many meters of horizontal cabling?
  • What term describes the location where a flat under-carpet cable connects to the ground horizontal cable?
  • The maximum length specified for the work area cabling is?
  • During a service call, which test is performed by connecting a field certification tester to the cords at both ends to verify installation integrity?
  • Which color combination is specified for Group 6 ribbons in a 300-pair UTP backbone binder?
  • Which statement about zone cabling in open office design is true?
  • TIA stands for what?
  • Power Sum NEXT is the undesired coupling of signal energy from a number of simultaneously transmitting pairs into a receiving pair. Which term matches this description?
  • Which statement about administration label color for the first level backbone cable is correct?
  • Which statement best describes the Transition Point in cabling terms?
  • What type of connection is typically used to connect terminal blocks, patches, and equipment ports within equipment rooms?
  • Which item is not considered part of horizontal pathways components?
  • What is the standard for Outside Plant?
  • Which cables are not recognized for horizontal cabling?
  • What is the maximum length allowed for UTP data backbone cables according to the guideline?
  • In computers and equipment rooms, the floor system with modular panels supported by pedestals, with or without stringers is called?
  • What device provides a centralized point to connect multiple cables within a distribution area?
  • A busbar placed in convenient and accessible location and bonded to power service equipment ground is called?
  • Which field testing category is used to guarantee that the cabling system will not cause network problems, provides a guarantee that the system will meet network specifications, and documents the test results?
  • Bridged tabs are not allowed in horizontal cabling.
  • TIA stands for what?
  • Overcurrent protection is provided either by heat coil or fuses.
  • How many binder groups are there in 200-pair UTP backbone cable?
  • Which unit is used to express the ratio of two signal levels on a logarithmic scale?
  • The administrative requirements of the telecommunications infrastructure are specified by which standard?
  • The residential telecommunications infrastructure standard is TIA-570.
  • Which statement about the telecommunications room is true?
  • The minimum bend radius for MULTI-PAIR cable should be
  • Which component serves as the foundation of the telecommunications grounding system and interfaces between the building service equipment ground and the telecommunications infrastructure?
  • The __ shall bond the PBB to the server equipment (power) ground.
  • In telecom cabling terminology, which term represents the device that allows the customer to disconnect from the service?
  • Which of the following is an element of the commercial building tech cabling system, suitable for selection as an example?
  • Which unit is a logarithmic measure commonly used for comparing power or voltage levels?
  • _______________ is an undesired coupling of signal energy from a number of simultaneously receiving pairs into a receiving pair measured at a opposite end of the cable from where the transmitter is located?
  • Which fire-stop design uses a frame with modular inserts that are compressed to seal around the cable?
  • In a 300-pair UTP backbone cable binder, group 6 is wrapped with two plastic ribbons. Those colors are.
  • Which component is primarily used for cross-connecting circuits in data networks?
  • Performance requirements for classic FA, cable, connectors, basic links, and channels are specified at frequencies between?
  • Residential cabling installations are governed by which standard?
  • Which NEC Chapter covers Telecommunications?
  • Which item is part of the intra-building backbone as an element of the cabling system?
  • Which of the following best describes a horizontal pathway?
  • For NEXT at a given 8-pin modular outlet, as frequency increases, NEXT ______?
  • Which statement about space requirements is true?
  • The Secondary Bonding Busbar is located in which rooms?
  • According to the TIA-568.2-D standard, the test referred to as a Channel test is performed by disconnecting the patch cable and connecting a field certification tester to the cords at both ends during a service call.
  • A busbar that is placed in each telecom and equipment rooms is called a:
  • The administrative color label for common equipment ports?
  • The purpose of different twist lengths is to minimize __________ among pairs.
  • What term denotes the unwanted signal coupling from one balanced twisted-pair path to another?
  • The poke method is highly recommended because it is quick and easy.
  • What does SBB stand for?
  • Which field testing category is used to ensure the cabling will support a given network technology?
  • What is the grounding connection point of the telecommunication system in the area served by the telecommunication room?
  • TIA standard methods for terminating twisted pair cable on 8-pin modular outlets include?
  • What is the stated purpose of giving each pair in a twisted-pair cable a different twist length?
  • Which device converts data into code?
  • When terminating Cat5 and higher cables, the cable pair twists shall be maintained within how many millimeters from the termination point?
  • Which term is commonly used to express the ratio of two power levels in telecommunications?
  • The acronym TBC stands for which term?
  • For a given 8 pin modular outlet as frequency increases NEXT____________?
  • Which of the following is a valid pair of wiring schemes used for 8-pin modular outlets according to TIA standards?
  • The functions of a telecom room may also be performed in a?
  • The administrative color label for second level backbone cable is?
  • Which organization defines the termination schemes T-568A and T-568B for twisted-pair cabling?
  • Which standard covers commercial telecom cable, bonding and grounding?
  • The backbone cable is used to provide interconnection between which locations?
  • TIA/EIA 569-B Standard covers which topic?
  • According to TIA 606C, all inter-building backbone cables (campus cabling), shall be identified with the color?
  • What term describes the portion of the telecommunications cabling system that runs from the work area outlet to the horizontal cross-connect in the telecom room?
  • The grey/green plastic box mounted to many homes and serves as a demarcation point for the local carrier is called a network interface device. True or False?
  • Overall voltage protectors in UTP cables are designed to provide a
  • _____________ crosstalk is the coupling of unwanted signals between cables in a bundle and is the most prevalent at frequencies above 400 MHz.
  • For a given outlet as frequency increases, attenuation _____________?
  • In campus cabling, the conductor type that interconnects bonding and grounding to building power ground is the ...?
  • In grounding, which component can serve as the interface between the building service equipment ground and the telecommunications infrastructure?
  • What is the minimum distance from the floor to lowest 110 Block during the layout?
  • Which term describes the difference in delay between the fastest and slowest twists within a cabling pair?
  • Which term describes the coupling of unwanted signals between cables in a bundle that becomes most prevalent above 400 MHz?
  • What is the primary objective of the NEC?
  • Chapter 100 of the NEC is associated with what topic?
  • NEC stands for what?
  • Which NEC article covers grounding?
  • Which type of IBM cable consists of two 22 AWG, solid copper twisted pairs, each individually shielded with foil, with a braided outer shield surrounding the entire cable core, and covered with a jacket?
  • Which of the following is the minimum conductor size for a Telecommunications Bonding Backbone (TBB)?
  • What does SBB stand for in telecom grounding?
  • Which test validates the continuity of the entire cabling link?
  • UTP cables shall be terminated on 8-position/ 7-conductor outlets using the ____________?
  • What term describes the amount of signal energy reflected back to the transmitter due to impedance discontinuities in a twisted pair?
  • Attenuation is the reduction of optical power as it propagates through an optical fiber. Which term describes this effect?
  • Which standard covers Residential Telecom Cabling?
  • In NEC what article can you find definitions?
  • What is the minimum inside radius of the bonding conductor terminated at the TBB or SBB?
  • _________ cables are not recognized for use in horizontal cabling.
  • A busbar placed in a convenient and accessible location, and bonded to the power service equipment ground is:
  • At frequencies above which value does alien crosstalk start to affect cabling performance?
  • KCmil stands for kilo circular mil, a unit used to describe conductor cross-sectional area. Which option correctly identifies this abbreviation?
  • In a video distribution system, the effect of adding a pass-through device or splitter on the video signal is to what?
  • The primary function of a telecommunication room is the termination of horizontal backbone cables to compatible hardware.
  • Which term describes the protective objective of the NEC?
  • Which field testing verifies that the cabling link meets basic connection or continuity requirements?
  • Which two labeling schemes are commonly used for terminating twisted pair cables on 8-pin modular outlets?
  • What is the term for the difference between the delays of the fastest and slowest twisted-pair conductors within a cable?
  • Bonding conductors shall be copper and insulated with a gray jacket or marked with a green color using vinyl tape.
  • What section of the NEC defines the working clearances around electrical equipment?
  • A GENERIC telecommunication system that supports a multi-vendor multi-product environment describes which standard?
  • A contractor requires warranty; the testing is categorized as what?
  • In a multi-story building, which conductor is used to interconnect the telecommunications bonding backbone across floors?
  • By allowing each of the pairs in twisted pair cables to have a different twist length, the degree of which phenomenon is reduced?
  • Which statement is true about splices in telecom bonding when they are necessary?
  • The TBB should be installed without splices. If splices are necessary, the splice shall be?
  • Each end of the horizontal cable shall be labeled within how many inches of the end of the cable jacket?
  • Which statement about the NEC's scope is correct?
  • Residential telecommunications infrastructure standard?
  • When configuring an equipment rack in the TR, it is recommended that a 1U horizontal cable management device be installed every other?
  • Which component bonds the PBB to the server equipment grounding path?
  • A __________ is a device that converts data into code.
  • Which standard would you consult for residential guidelines for home cabling?
  • Commercial building's grounding and bonding requirements for telecommunications:**
  • Which standard specifies the administration requirements for a uniform telecommunication, and grounding and bonding infrastructure that shall be followed within commercial buildings where telecommunication equipment will be installed?
  • In horizontal cabling, the consolidation point interconnects which segments?
  • Which field testing assures that the installed cabling link will transmit data using a specific network technology?
  • Which standard covers unshielded twisted pair cabling components?
  • The performance requirement for Cat5 cables connectors, basic links and channels is specified at frequencies up to what?
  • A-Bus Hubs support up to _______ zones.
  • Which NEC Chapter covers Bend Radius?
  • Which standard specifies the requirement for a uniform telecommunication grounding and bonding infrastructure within commercial buildings?
  • ATI/EIA Standard 750 covers?
  • In cabling performance metrics, which quantity compares the received power to the NEXT power?
  • The newer Type 1A cables are specified to frequencies up to what?
  • A busbar placed in each telecommunication room and equipment room is called?
  • Which NEC Chapter covers Fire Alarms?
  • The minimum bending radius for a bonding conductor is eight times the outside diameter of the conductor.
  • The Primary Bonding Busbar is bonded to which ground?
  • Permanent link is defined as
  • Original Type 1 cables were specified up to which frequency?
  • Access to the electrical ground shall be provided within how many feet of the distribution device?
  • The maximum allowable length for any UTP data backbone cable is
  • The functions of a telecom room may be performed in which other space?
  • Residential Telecom Infrastructure is addressed by which standard?
  • The following statement is true: The maximum length for work area cabling is 16 feet.
  • The cross-connect facility used for termination and connection of outlet cables, DD cords, equipment cords, and sometimes ADO cables is abbreviated as what?
  • Which standard covers bonding and grounding of commercial telecom installations?
  • A __________ consists of up to 90 meters of horizontal cabling, a connection at each end, up to 2 meters of test equipment cord from the main unit of the field tester to the local connection, and up to 2 meters of test equipment cord from the remote connection to the remote unit of the field tester.
  • The conductor that interconnects the telecommunication bonding and grounding infrastructure to the building's power source equipment ground is the?
  • Which standard is associated with the administration of telecommunication infrastructure?
  • All conduit ends are to be reamed and bushed.
  • Which term describes the raised floor system used to support modular panels in computing facilities?
  • ACRF is an undesired coupling of signal energy from a transmitting pair into a receiving pair, measured at the opposite end of the cable from where the transmitter is located.
  • Which field testing category ensures that a cabling link meets performance requirements defined by industry standards?
  • Which standard is used to govern grounding and bonding of telecommunications in commercial buildings?
  • The NEC chapter that deals with the general requirements of communications systems is?
  • Standards are ______ and codes are ______?
  • TMGB stands for what in telecommunications grounding?
  • Horizontal pathways may be installed in ceilings or in?
  • Which of the following is associated with the administrative requirements of telecommunications infrastructure?
  • The ____________ test configuration is to be used by system designers and users of data communications systems to verify the performance of the overall 'channel'.
  • What term describes the path used to install telecommunications cables from a telecom room to work area outlets?
  • Which color label is reserved for identifying common equipment ports?
  • Structure cabling standards allow for __ equipment rooms per building?
  • Pathways and Spaces is addressed by which standard?
  • A blue color label on a horizontal cable indicates which of the following?
  • Article 760 covers the requirements for the installation of wiring and equipment of which system?
  • Article 800 in the NEC covers which topic?
  • Which component provides a common grounding point within the telecommunications room?
  • Mandatory requirements are designated by which word?
  • Which option lists the maximum size of a bonding conductor in KCmil with the correct maximum being 750 KCmil?
  • Bridged tabs are allowed in horizontal cabling.
  • Zone cabling is a viable option for supporting open office work areas.
  • A busbar placed in each telecom room and equipment room is called?
  • Which standard is used for terminating UTP on 8P/7C outlets?
  • Which option describes the shield arrangement of IBM Type-1 cable's core?
  • The administration label color for first level backbone cable is?
  • Which standard defines pathways and spaces?
  • As bit rate increases, the required bandwidth changes which way?
  • The performance requirements for Cat 3 cable, connectors, basic links and channels are spot frequencies of up to
  • In horizontal cabling for open offices, what is the consolidation point primarily used for?
  • The bandwidth of a multi-mode fiber is expressed in which unit?
  • Which term describes undesired coupling from several receiving pairs into a single receiving pair?
  • In a residential outage, which component disconnects the premise cabling from the provider network?
  • The home-run method is NOT for running horizontal cables in floors.
  • Which primary field test parameter will likely be adversely affected by exceeding the bend radius or mishandling of a cable during installation?
  • Which standard governs building cabling installations?
  • The ______ is the approximate speed at which a signal moves through a cable, crucial for accurate length measurements.
  • What does EIA stand for according to the provided material?
  • Compared to Multi-Mode fiber, the core of a Single-Mode fiber is
  • A unit of measure used to express a ratio between two voltages or power is called?
  • Fiber cabling components are specified by which standard?
  • Conductor connectivity among terminal blocks, patches, panels, and equipment ports is usually accomplished with which type of cable?
  • Which term is the ratio of the power of the signal received over the power of the NEXT from the local transmitter?
  • Which NEC Chapter covers Definitions?
  • What does MUTOA stand for?
  • (T/ F) Cross connects may be made between any of the fields present in the Telecom Room.
  • Advisory requirements are designated with the word
  • The minimum bend radius rule for Multi-Pair cable is stated as a multiple of the cable's diameter. It should be
  • Which standard is commonly used to describe Residential Telecom Cabling in this context?
  • The _________ standard defines the requirements for an administration system.
  • Which of the following is NOT one of the five areas to be administered in telecommunications infrastructure?
  • A __________ consists of up to 90 meters of horizontal cable, a work area, equipment cord, a telecommunication outlet, and an optional consolidation point connection close to the work area and two cross-connect connections in the telecommunication room.